| Site Map Home Page |
Smock & Schonthaler
|
|||||||||||||||||||
|
Industrial Insulation Sales, Inc.
|
||||||||||||||||||||
|
2320 Warfel Ave. • Erie, Pennsylvania 16503 • Toll Free: 1-800-734-8771 • Local Phone • (814) 456-4222 • Fax: (814) 456-8346
E-MAIL DIRECTORY: |
||||||||||||||||||||
|
|
||||||||||||||||||||
|
Theatre Example
|
||||||||||||||||||||
|
Absorption value
Existing 520 s.f. carpet at .15 320 s.f. curtains at .30 to .35 2000 s.f tectum at .35 Total existing absorption 882 sabins Sabins required for a 1 second reverb time is 1325 minus the existing of 882 = 443 sabins for a 1 second reverb time or half of that for the 2 second reverb time. Our fabric covered wall panel absorbs .8 per s.f. so you need about 34 ea. 2’ x 4’ x 1” or a total of 275 s.f. of absorber with an NRC of .8 to get to the 2 second reverb (preferred) reverberation. Certainly any quantity of 80% of this number will have a recognizable impact. Start with something that will make a difference and add more if you want. This works. |
||||||||||||||||||||
|
WEBMASTER: Internet Marketing Resources, Inc.
|
||||||||||||||||||||